top of page
Oil Contamination Monitor and Water Sensor (VH-OCM)

Oil Contamination Monitor and Water Sensor (VH-OCM)

The Vens VH-OCM monitors the condition of hydraulic and lube oil while the machine runs, so you act on trends instead of waiting for a laboratory report. The particle monitor counts particles in the oil flowing through it and reports the cleanliness code; the water sensor reports the water content as a percentage of saturation, together with the oil temperature.

Technical data

  • Particle monitor output: ISO 4406, SAE AS4059 and NAS 1638 codes
  • Measuring range: ISO 4406 codes 10/9/8 to 24/23/22
  • Accuracy: within one ISO class in the calibrated range
  • Operating pressure: up to 210 bar
  • Water sensor: 0 to 100 % saturation, with oil temperature
  • Signals: 4 to 20 mA, switching outputs and RS-485
  • Installation: fixed on the machine, on an offline filter unit, or on a portable case for spot checks

Model code

VH-OCM – type – output

  • Type: P = particle monitor, W = water sensor, PW = both
  • Output: A = 4 to 20 mA, R = RS-485

Example: VH-OCM-PW-A

Where it is used

  • Turbine and compressor lube oil
  • Hydraulic power units and test rigs
  • Flushing and commissioning of new systems
  • Filter carts and offline filter units, to show when the oil is clean

Tell us the fluid, the pressure at the measuring point and the signals your control system takes, and we will configure the monitor. Pair it with a VH-OLF offline filter unit.

Models

  • VH-OCM-P: particle monitor
  • VH-OCM-W: water sensor, % saturation and temperature
  • VH-OCM-PW: both, in one installation
  • Flow through the monitor: about 50 to 400 mL/min
  • Supply: 24 V DC

Options

  • Portable case for spot checks
  • Display unit with data logging
  • Fitting on an offline filter unit (VH-OLF)

What to send for a quotation

  • Oil and system pressure
  • What you want to measure: particles, water or both
  • Signal needed: 4 to 20 mA or RS-485
  • Quantity

Figures are typical and may change without notice. Actual performance depends on the liquid and the duty, on installation and use in line with the operation manual, and on site conditions; we confirm the figures for your duty in our offer.

See the full Vens filter range, or look up an equivalent element in FilterDex.

Certification: Vens Hydroluft is certified to ISO 9001:2015 and ISO 14001:2015, holds ASME and PED pressure vessel certification, and complies with FDA and EU food safety regulations.

Vens has more than 10,000 installations. Every unit is designed by engineers who studied at MIT, Stanford, Cornell, the IITs, Arizona State University and the University of Cincinnati and have worked in the industries that use this equipment, so it is sized for the job, built in the right materials and designed to proper factors of safety.

    ₹0,00Fiyat
    Adet
    bottom of page