top of page
Filter Clogging Indicators (VH-CIN)

Filter Clogging Indicators (VH-CIN)

A clogging indicator tells you when a filter element needs changing, before the bypass valve opens and dirty oil passes. The Vens VH-CIN range covers differential pressure indicators for pressure and return line filters and vacuum indicators for suction filters, in visual, electrical and combined forms. They are supplied fitted to Vens filters or as spares and retrofits.

Technical data

  • Types: visual pop-up, electrical switch, visual-electrical, vacuum gauge or switch
  • Switching points: 1.5, 2, 3.5 or 5 bar differential; −0.2 bar for suction
  • System pressure: up to 315 bar for pressure filter indicators
  • Electrical: changeover contact; DIN or M12 connector
  • Options: thermal lock-out to stop false signals at cold start; manual or automatic reset

Model code

VH-CIN – type – setting

  • Type: V = visual, E = electrical, VE = both, S = suction
  • Setting: differential pressure in bar

Example: VH-CIN-VE-5.0

Where it is used

  • Pressure, return and suction line filters
  • Duplex and lube oil filters
  • Offline filter units and filter carts

Tell us the filter make and model, the connection and the signal you need, and we will match the indicator.

Models

  • VH-CIN-V: visual pop-up, manual or automatic reset
  • VH-CIN-E: electrical switch, changeover contact
  • VH-CIN-VE: visual and electrical in one body
  • VH-CIN-S: vacuum gauge or switch for suction filters
  • Settings: 1.5, 2, 3.5 or 5 bar differential; −0.2 bar for suction
  • Electrical rating: 24 V DC or 230 V AC

Options

  • Thermal lock-out below about 30 °C
  • LED connector
  • Adaptor bodies to fit other makes of filter

What to send for a quotation

  • Filter make and model
  • Connection thread or port
  • Setting and signal needed
  • Quantity

Figures are typical and may change without notice. Actual performance depends on the liquid and the duty, on installation and use in line with the operation manual, and on site conditions; we confirm the figures for your duty in our offer.

See the full Vens filter range, or look up an equivalent element in FilterDex.

Certification: Vens Hydroluft is certified to ISO 9001:2015 and ISO 14001:2015, holds ASME and PED pressure vessel certification, and complies with FDA and EU food safety regulations.

Vens has more than 10,000 installations. Every unit is designed by engineers who studied at MIT, Stanford, Cornell, the IITs, Arizona State University and the University of Cincinnati and have worked in the industries that use this equipment, so it is sized for the job, built in the right materials and designed to proper factors of safety.

    Rs 0,00Harga