Catalyst Recovery Filter Systems (VH-CRF)

Catalyst Recovery Filter Systems (VH-CRF)

The Vens VH-CRF separates solid catalyst from the reaction liquid and keeps it for reuse. Slurry from the reactor flows through rigid sintered metal candles in a closed vessel; the catalyst forms a cake on the candles and clear product leaves. The cake is then backwashed with liquid or blown back with nitrogen, either straight into the reactor or out as a concentrated slurry. Everything happens inside a closed, inerted system, so pyrophoric catalysts such as Raney nickel and palladium on carbon are never exposed to air, and none is lost with the product.

Technical data

  • Designs: batch (filter, wash, blow dry, discharge) or continuous (two or more banks, one cleaning while the others filter)
  • Candles: sintered 316L powder, 1 to 20 µm, or five-layer sintered mesh, 5 to 40 µm; Hastelloy and other alloys for corrosive duties
  • Catalysts: palladium and platinum on carbon, Raney nickel, nickel, copper and other slurry catalysts
  • Cleaning: automatic liquid backwash or nitrogen blowback, started by differential pressure or timer
  • Vessel: stainless steel 316L or alloy; designed to ASME Section VIII Division 1 or PED when the order calls for it
  • Controls: PLC with automatic valves, inert gas blanketing, differential pressure and level instruments
  • Supply: skid with vessel, valves, piping, instruments and controls; sized for your process, where possible after a filtration test on a sample

Model code

VH-CRF – mode – number of candles – media – rating (µm)

  • Mode: B = batch, C = continuous
  • Media: P = sintered powder, M = sintered mesh

Example: VH-CRF-C-19-P-5

Where it is used

  • Hydrogenation in pharmaceutical and fine chemical plants
  • Hydrogen peroxide (anthraquinone) process
  • Edible oil and oleochemical hydrogenation with nickel catalyst
  • Catalyst retention in continuous stirred reactors
  • Oxidation processes with slurry catalysts

Tell us the reactor size and batch volume or flow, the catalyst, its loading and particle size, the liquid, the temperature and pressure, and whether the catalyst goes back to the reactor or out of the plant. Replacement candles: VH-SNP sintered powder and VH-SNM sintered mesh.

Models and sizes

  • Candles per vessel: about 7 to 100
  • Filter area: about 1 to 30 m² per vessel
  • Batch systems: one vessel; filter, wash, blow dry and discharge in turn
  • Continuous systems: two or more banks; one cleaning while the others filter

Options

  • Filtration test on your slurry
  • ASME VIII Div 1 or PED vessel
  • Heating jacket
  • Hastelloy candles
  • Factory acceptance test

What to send for a quotation

  • Process and fluid, with temperature and pressure
  • Flow and solids load
  • What happens to the solids: returned, recovered or discarded
  • Design code and materials
  • A sample for a filtration test, where possible
  • Quantity

Figures are typical and may change without notice. Actual performance depends on the liquid and the duty, on installation and use in line with the operation manual, and on site conditions; we confirm the figures for your duty in our offer.

See the full Vens filter range, or look up an equivalent element in FilterDex.

Certification: Vens Hydroluft is certified to ISO 9001:2015 and ISO 14001:2015, holds ASME and PED pressure vessel certification, and complies with FDA and EU food safety regulations.

Vens has more than 10,000 installations. Every unit is designed by engineers who studied at MIT, Stanford, Cornell, the IITs, Arizona State University and the University of Cincinnati and have worked in the industries that use this equipment, so it is sized for the job, built in the right materials and designed to proper factors of safety.