High Pressure Duplex Changeover Filter (VH-HPD)

High Pressure Duplex Changeover Filter (VH-HPD)

The Vens VH-HPD has two filter bowls under one head with a changeover valve. One side filters while the other stands by, so an element can be changed without stopping the machine. A pressure-balancing valve equalises the two sides before changeover, so the lever moves smoothly under pressure.

Technical data

  • Maximum operating pressure: up to 210 bar
  • Flow: up to 200 L/min
  • Filter media: glass fibre 5, 10 or 20 µm; stainless steel mesh 25 to 80 µm
  • Changeover: lever-operated valve with pressure balancing
  • Clogging indicator: one per side; visual, electrical or both
  • Temperature: −10 to 90 °C
  • Seals: NBR or FKM (Viton)
  • Vents and drains: on both bowls

Model code

VH-HPD – size – media – indicator

  • Media: G05, G10, G20 = glass fibre; W25 to W80 = wire mesh
  • Indicator: V = visual, E = electrical, VE = both

Example: VH-HPD-150-G10-VE

Where it is used

  • Continuous process plants: steel, paper, power
  • Turbine control and lube oil systems
  • Hydraulic systems that cannot be stopped for maintenance

Tell us the pressure, the flow and the fluid. For low pressure lube oil duties, see the Vens duplex filter housings.

Models and sizes

  • Size 60: up to 60 L/min
  • Size 110: up to 110 L/min
  • Size 150: up to 150 L/min
  • Size 240: up to 200 L/min
  • Basis: flows for mineral oil at 30 cSt with 10 µm glass fibre

Options

  • Electrical indicators to the control room
  • FKM (Viton) seals
  • Manifold or inline ports
  • Spare elements

What to send for a quotation

  • System flow and maximum pressure
  • Fluid and its viscosity
  • Cleanliness needed (ISO 4406 code or µm)
  • Port size and mounting
  • Bypass and indicator needed
  • Quantity

Figures are typical and may change without notice. Actual performance depends on the liquid and the duty, on installation and use in line with the operation manual, and on site conditions; we confirm the figures for your duty in our offer.

See the full Vens filter range, or look up an equivalent element in FilterDex.

Certification: Vens Hydroluft is certified to ISO 9001:2015 and ISO 14001:2015, holds ASME and PED pressure vessel certification, and complies with FDA and EU food safety regulations.

Vens has more than 10,000 installations. Every unit is designed by engineers who studied at MIT, Stanford, Cornell, the IITs, Arizona State University and the University of Cincinnati and have worked in the industries that use this equipment, so it is sized for the job, built in the right materials and designed to proper factors of safety.