A new or modified pipeline is full of weld spatter, scale and debris that will damage pumps, valves and meters at start-up. The Vens VH-CST is a perforated cone or basket fitted between two flanges for the commissioning period, then removed once the line runs clean. A tab on the ring shows from outside that a strainer is fitted.

Technical data

  • Sizes: 2 to 20 inch
  • Flange classes: ASME Class 150 and 300
  • Types: cone (pointing upstream or downstream) and flat-bottom basket
  • Perforations: 1/16 to 1/2 inch
  • Mesh linings: 20 to 80 mesh
  • Materials: stainless steel 304 or 316
  • Identification: extended tab on the ring

Model code

VH-CST – type – size – class – perforation – mesh

  • Type: C = cone, B = basket
  • Size: in inches
  • Class: 150 or 300
  • Mesh: 0 = none, or mesh number

Example: VH-CST-C-6-150-1/8-40

Where it is used

  • Commissioning of new process and utility pipelines
  • Restarting lines after maintenance or modification
  • Protecting pumps, control valves and meters during flushing

Tell us the pipe size, the flange class and the debris you expect. For permanent protection, see the Y strainer and basket strainers.

Models and sizes

  • Sizes: 2 to 20 inch
  • Cone open area: about 150 to 300 % of the pipe area
  • Basket open area: about 200 to 400 % of the pipe area
  • Perforations: 1/16, 1/8, 1/4 or 1/2 inch
  • Mesh linings: 20, 40, 60 or 80 mesh
  • Thickness: 1.5 to 3 mm sheet, set by size and class

Options

  • Extended tab stamped with size, class and mesh
  • SS 316
  • Spiral-wound gasket set

What to send for a quotation

  • Pipe size and flange class
  • Liquid and flow
  • Debris expected and mesh needed
  • Quantity

Figures are typical and may change without notice. Actual performance depends on the liquid and the duty, on installation and use in line with the operation manual, and on site conditions; we confirm the figures for your duty in our offer.

See the full Vens filter range, or look up an equivalent element in FilterDex.

Certification: Vens Hydroluft is certified to ISO 9001:2015 and ISO 14001:2015, holds ASME and PED pressure vessel certification, and complies with FDA and EU food safety regulations.

Vens has more than 10,000 installations. Every unit is designed by engineers who studied at MIT, Stanford, Cornell, the IITs, Arizona State University and the University of Cincinnati and have worked in the industries that use this equipment, so it is sized for the job, built in the right materials and designed to proper factors of safety.

    ₹ 0,00Preço
    Quantidade
    bottom of page