Electrolyser Porous Transport Layers and Hydrogen Filters (VH-ELP)

Electrolyser Porous Transport Layers and Hydrogen Filters (VH-ELP)

In a PEM electrolyser the porous transport layer (PTL) sits between the anode catalyst layer and the bipolar plate. It carries water in, oxygen out and current across, in conditions so oxidising that it has to be made of titanium. The Vens VH-ELP covers sintered titanium PTLs for PEM cells, sintered nickel and stainless steel porous layers for alkaline and AEM cells, and sintered metal filters for the hydrogen and oxygen lines.

Technical data

  • Titanium PTLs: sintered titanium powder, thickness 0.25 to 1.0 mm, porosity 15 to 40%
  • Sizes: cut to your cell; thickness and flatness to your drawing
  • Nickel and stainless layers: sintered nickel or 316L, for alkaline and AEM electrolysers
  • Gas filters: sintered 316L elements for hydrogen and oxygen outlets, from 1 µm
  • Supply: samples and small batches for stack development, then production quantities

Model code

VH-ELP – type – thickness (mm)

  • Type: T = titanium PTL, N = nickel layer, S = stainless layer, G = gas filter

Example: VH-ELP-T-0.5

Where it is used

  • PEM electrolyser stacks (anode PTL)
  • Alkaline and AEM electrolysers
  • Hydrogen and oxygen gas-line filters
  • Electrochemical test cells and pilot stacks

Send us the cell drawing and active area, the thickness and porosity you need, any coating requirement and the quantity. For inline gas filters, see the VH-SNL inline sintered filter.

Models and sizes

  • Titanium PTLs: 0.25 to 1.0 mm thick; porosity 15 to 40 %
  • Sizes: from test cells of 25 cm² to production cells, cut to your drawing
  • Nickel and 316L layers: for alkaline and AEM cells
  • Gas filters: sintered 316L, from 1 µm

Options

  • Flatness and thickness reports
  • Samples for stack trials
  • Gas filter housings to suit

What to send for a quotation

  • Cell type and active area
  • Thickness and porosity wanted
  • Quantity for trials and for production

Figures are typical and may change without notice. Actual performance depends on the liquid and the duty, on installation and use in line with the operation manual, and on site conditions; we confirm the figures for your duty in our offer.

See the full Vens filter range, or look up an equivalent element in FilterDex.

Certification: Vens Hydroluft is certified to ISO 9001:2015 and ISO 14001:2015, holds ASME and PED pressure vessel certification, and complies with FDA and EU food safety regulations.

Vens has more than 10,000 installations. Every unit is designed by engineers who studied at MIT, Stanford, Cornell, the IITs, Arizona State University and the University of Cincinnati and have worked in the industries that use this equipment, so it is sized for the job, built in the right materials and designed to proper factors of safety.