top of page

ATEX temperature classes T1 to T4: what they mean for an oil skimmer

6 days ago
4 min read

The temperature class (T class) on an ATEX or IECEx nameplate gives the hottest surface temperature the equipment can reach. It must stay below the ignition temperature of the gas or vapour that may be present. T1 allows surfaces up to 450 °C; T4 allows only 135 °C. For an oil skimmer in a refinery pit or a tank farm, the site's hazardous area classification sets the class, and the skimmer's motor, gearbox and controls must match it.

What the T class means

Any machine warms up as it runs. A surface that is hot enough can ignite a flammable gas or vapour without a spark. The temperature class caps the maximum surface temperature of the equipment, so that it stays below the point at which the gases in the area would ignite on their own.

The six temperature classes

Class

Maximum surface temperature

Ignition temperature of the gas

Typical substances

T1

450 °C

above 450 °C

Methane, hydrogen, ammonia, acetone, benzene, toluene

T2

300 °C

above 300 °C, up to 450 °C

Ethylene, acetylene, n-butane, ethanol

T3

200 °C

above 200 °C, up to 300 °C

Petrol, diesel, kerosene, fuel oil, hydrogen sulphide, hexane

T4

135 °C

above 135 °C, up to 200 °C

Acetaldehyde, diethyl ether

T5

100 °C

above 100 °C, up to 135 °C

Few common substances

T6

85 °C

above 85 °C, up to 100 °C

Carbon disulphide

Published ignition temperatures differ slightly between sources. Use the figures in your site's area classification documents.

How to choose

A higher class number means a cooler surface. Equipment rated T4 can be used wherever T1, T2 or T3 is required. Equipment rated T1 can be used only where every gas present ignites above 450 °C.

The rule is simple: find the gas or vapour in the area with the lowest ignition temperature, and choose a class whose maximum surface temperature is below it.

Most hydrocarbon areas in refineries, depots and tank farms handle petrol, diesel or kerosene, which fall in T3. Equipment rated T3 or T4 covers them.

Zones and gas groups: the other two parts of the rating

The T class is one of three things a hazardous area classification sets:

  • Zone: how often an explosive atmosphere is present. Zone 0 is continuously or for long periods, Zone 1 is likely in normal operation, and Zone 2 is not likely, and only briefly if it occurs.

  • Gas group: how easily the gas is ignited by a spark or flame. IIA covers propane, petrol and diesel; IIB covers ethylene and hydrogen sulphide; IIC covers hydrogen and acetylene. IIC equipment can also be used in IIB and IIA areas.

  • Temperature class: T1 to T6, as above.

A typical IECEx marking reads Ex db IIB T4 Gb:

  • Ex db is the type of protection, here a flameproof enclosure.

  • IIB is the gas group.

  • T4 is the temperature class.

  • Gb is the equipment protection level, suitable for Zone 1.

ATEX equipment also carries a category marking such as II 2 G, meaning surface industry (II), category 2 (Zone 1) and gas (G).

What it means for an oil skimmer

The parts of a skimmer that could heat up or spark are the electric motor, the gearbox, any level switch or heater, the terminal box and the control panel. Under ATEX, non-electrical parts such as gearboxes and couplings are assessed as well as the electrics.

There are three common ways to make a skimmer suitable for a hazardous area:

  • Certified electric drive: an ATEX or IECEx motor of the right gas group and T class, with certified terminal box and cable glands. The control panel goes outside the zone or is certified itself.

  • Air motor drive: compressed air from outside the zone drives the skimmer, so there are no electrics at the skimmer. See the pneumatic floating drum skimmer.

  • Hydraulic drive: the skimmer runs on hydraulic motors and the power pack stands outside the zone. See the hydraulic floating drum skimmer and the Orbis Pro hydraulic disc skimmer.

In all three cases, the skimmer frame is earthed and bonded so that static charge cannot build up.

The temperature of the liquid matters too. A skimmer working in hot oil has wetted parts at the oil temperature, so tell us the liquid temperature as well as the ambient range.

Vens supplies skimmers for hazardous areas with ATEX-certified drive components rated T1 to T4, and with air or hydraulic drives where electrics are not wanted in the zone. The area classification, gas group and temperature class are set by the site owner, and are part of our quotation only where you specify them.

What to send us

  • Zone: 0, 1 or 2

  • Gas group: IIA, IIB or IIC

  • Temperature class required

  • Ambient temperature range and liquid temperature

  • Power available at the skimmer: electric, compressed air or hydraulic

  • Any national approval your site needs. In India, electrical equipment for petroleum hazardous areas often needs PESO approval as well.

Questions buyers ask

Is T4 better than T3?

T4 equipment runs cooler, so it can be used in more places. If your area classification asks for T3, T3 equipment is correct and T4 is not required.

Does the T class depend on the ambient temperature?

Yes. The rating holds within the ambient range on the nameplate, usually −20 °C to +40 °C. For hotter sites, or for equipment near hot liquids, the range has to be checked.

Can a belt or disc skimmer run in Zone 0?

The belt or disc can work in the liquid, but drives and electrics are not normally placed in Zone 0. The usual solution is to mount the drive outside the zone, or to use an air or hydraulic drive.

For a skimmer to suit your hazardous area, send us your details with the zone, gas group and temperature class, and we will come back with a proposal.

Comments