If the line can stop for a few minutes while the element is cleaned, a simplex filter housing is enough. If it cannot, because a turbine, compressor, burner or production line depends on it, you need a duplex filter housing: two chambers and a changeover valve, so one side filters while the other is serviced. This guide explains how each works, how to choose between them, and how to size either one.

Vens duplex filter housings with changeover valves

At a glance

  • Simplex: one chamber, one element or basket. Lowest cost and smallest footprint. The flow is stopped, or sent round a bypass, while the element is cleaned or replaced.

  • Duplex: two chambers joined by a changeover valve. One side is on line, the other on standby. The element is changed with the system running, so flow is never interrupted.

  • Choose duplex for lube oil to turbines, compressors and gearboxes, fuel oil to burners and engines, seal oil, cooling water and any hydraulic system on a continuous process.

  • Choose simplex for batch duties, transfer lines, test rigs and any system with a planned stop at least as often as the element needs attention.

How a simplex filter housing works

Liquid enters the housing, passes through the element from outside to inside (or through a basket from inside to outside) and leaves clean. As dirt builds up, the pressure drop across the element rises. When it reaches the change point, shown by a differential pressure gauge or a clogging indicator, the line is isolated, the housing is drained, and the element is cleaned or replaced.

Some plants fit a bypass line with valves round a simplex housing so that flow can continue during cleaning. It works, but the liquid that passes during that time is unfiltered. On a lube oil or servo hydraulic system that is exactly the dirt the filter is there to stop, so a bypass is a poor substitute for a duplex.

How a duplex filter housing works

A duplex housing has two filter bodies, each with its own element, joined by a three-way changeover valve (or a pair of linked valves). The valve is built so that one side is always open: during changeover both sides are briefly open together, so flow never stops.

A typical changeover runs like this:

  1. Open the small balancing (equalising) valve to fill the standby side with clean liquid and bring it to line pressure.

  2. Vent the air from the standby side through its vent valve.

  3. Move the changeover lever to bring the standby side on line.

  4. Close the balancing valve, drain the dirty side, open the cover and change or clean the element.

  5. Refit the cover, then fill and vent the side again so it is ready for the next change.

Skipping the filling and venting step is the most common cause of trouble: an empty or air-filled chamber put on line can cause a pressure dip at the bearings or a slug of air in the system. On high pressure duplex filters the balancing valve also equalises the pressure across the changeover valve, so the lever moves smoothly instead of fighting full system pressure.

For critical machinery, duplex filtration is often a requirement rather than a choice. Lube and seal oil systems built to API 614, for example, use twin full-flow filters with a transfer valve so an element can be changed without interrupting oil flow.

Simplex or duplex: side by side

Point

Simplex filter housing

Duplex filter housing

Stopping to change the element

Yes, or flow goes round an unfiltered bypass

No; the standby side takes over

Footprint and weight

Smaller and lighter

About twice the bodies, plus the changeover valve

Cost

Lower

Higher, offset by no downtime

Instruments

Pressure gauge or clogging indicator

Differential pressure gauge or indicator on each side, vents and drains on both bodies

Typical duties

Transfer lines, batch processes, test rigs, coarse protection

Turbine and compressor lube oil, fuel oil, seal oil, cooling water, continuous hydraulics

Spare element on site

Needed for a quick change

Needed; the standby side is not a spare

Sizing the housing and element

A filter housing is sized on flow and pressure drop, not on pipe size alone. Five things decide it:

  • Flow: the maximum, not the average, including any pump that can run at full output.

  • Viscosity: at the coldest operating condition, usually start-up. Oil at start-up can be several times thicker than at running temperature, and the pressure drop across the element rises with it. A thick oil, or a finer rating, often needs the next size up.

  • Rating: the particle size to be stopped. Wire mesh baskets (cleanable) suit coarser duties; glass fibre elements give fine filtration for hydraulic and lube oil; cellulose suits low pressure lube oil. See our guide to ISO 4406 cleanliness codes and filter ratings for choosing the micron rating.

  • Clean pressure drop: keep it low, so the element has plenty of margin before it reaches the change point. An element that starts close to its limit will need changing very often.

  • Design pressure and temperature: these set the body material, wall thickness and flange class.

Fit a differential pressure gauge or clogging indicator and change the element when it signals, not by the calendar. A clogging indicator with a thermal lock-out avoids false alarms from thick oil at cold start.

The Vens range

We design our housings in Canada and build them in our own facilities in Chennai, and we can build a duplex unit to suit the space and pipe connections of an existing simplex installation.

What to send us for a quotation

  • The liquid, its viscosity range and its temperature range

  • Maximum flow and the operating and design pressure

  • The particle size to be removed, or the cleanliness the equipment needs

  • Pipe size and flange class, and whether the existing housing is being replaced

  • Material preference and any standard to be followed (ASME, API 614, DIN)

  • Whether the line can stop for an element change

Questions buyers ask

Can a duplex filter replace a simplex filter in the same place?

Usually, if there is room for the second body. Send us the face-to-face dimension, flange details and the space available, and we will design the duplex unit to fit.

Can both sides of a duplex filter run at the same time?

The changeover valve opens both sides only briefly during changeover. In normal running one side filters and the other stands by clean, filled and vented, ready to take over.

Should I use a wire mesh basket or a glass fibre element?

Wire mesh is cleanable and suits coarser duties, from about 25 µm upwards. Glass fibre gives fine filtration, typically 5 to 25 µm, for hydraulic and lube oil where component life depends on cleanliness, and is replaced rather than cleaned.

How often should the element be changed?

When the differential pressure reaches the change point, not on a fixed schedule. A new system, or one recovering from a contamination event, will need changes more often at first.

Figures are typical and may change without notice. Actual performance depends on the liquid and the duty, on installation and use in line with the operation manual, and on site conditions; we confirm the figures for your duty in our offer.