Hot Gas Blowback Filters (VH-HGF)
The Vens VH-HGF removes dust and fine solids from gases that are too hot for fabric filter bags. The gas passes through rigid sintered metal candles hung from a tube sheet; the dust collects on the outside and clean gas leaves from the top. A short pulse of compressed air, nitrogen or process gas from inside each row of candles knocks the cake into the hopper, and a rotary valve or lock hopper takes it away. The gas can then be used hot, its heat recovered, and the collected solids returned to the process.
Technical data
- Temperature: up to 400 °C with 316L candles; up to 590 °C with Inconel 600 candles, in oxidising gas
- Candles: sintered metal powder or sintered fibre felt; gas grades from 1 µm
- Cleaning: reverse-pulse blowback with compressed air, nitrogen or process gas, started by differential pressure or timer
- Discharge: hopper with rotary valve, double dump valves or lock hopper
- Vessel: carbon steel, stainless steel or alloy, insulated; designed to ASME Section VIII Division 1 or PED when ordered
- Options: heat tracing to stay above the dew point; inert gas purge; candle failure safety filters
- Supply: sized for your process, where possible after a filtration test on a sample
Model code
VH-HGF – number of candles – candle material – grade (µm)
- Candle material: S = 316L, I = Inconel 600
Example: VH-HGF-36-S-2
Where it is used
- Catalyst fines in process gas from catalytic reactors
- Fluid bed dryers, calciners and kilns
- Recovery of fine powders and metal oxides
- Gasification and pyrolysis gas
- Vent gas from chemical and polysilicon processes
Tell us the gas flow, its temperature, pressure and composition, the dust load and particle size, and the outlet dust level you need. Replacement candles: VH-SNP and VH-SNF.
Models and sizes
- Candles per vessel: about 12 to 200
- Gas flow: about 200 to 20,000 Am³/h per vessel
- Filtration velocity: about 1 to 3 m/min, set by the dust
- Outlet dust: typically below 5 mg/Nm³
Options
- Heat tracing
- Inert gas purge
- Safety filters against candle failure
- Filtration test on your dust
- ASME VIII Div 1 or PED vessel
What to send for a quotation
- Process and fluid, with temperature and pressure
- Flow and solids load
- What happens to the solids: returned, recovered or discarded
- Design code and materials
- A sample for a filtration test, where possible
- Quantity
Figures are typical and may change without notice. Actual performance depends on the liquid and the duty, on installation and use in line with the operation manual, and on site conditions; we confirm the figures for your duty in our offer.
See the full Vens filter range, or look up an equivalent element in FilterDex.
Certification: Vens Hydroluft is certified to ISO 9001:2015 and ISO 14001:2015, holds ASME and PED pressure vessel certification, and complies with FDA and EU food safety regulations.
Vens has more than 10,000 installations. Every unit is designed by engineers who studied at MIT, Stanford, Cornell, the IITs, Arizona State University and the University of Cincinnati and have worked in the industries that use this equipment, so it is sized for the job, built in the right materials and designed to proper factors of safety.

_edited_edited.png)
.png)