Varnish in turbine and compressor oil: causes, testing and removal
Varnish is a thin, sticky, brown deposit that builds up on servo valves, bearings, filters and cooler surfaces in turbine, compressor and hydraulic systems. It makes valves stick, raises bearing temperatures and blocks fine clearances. In gas and steam turbines it is a common cause of failed starts and unexplained trips.
How varnish forms
As oil ages, heat and oxygen break some of it down into polar compounds. While the oil is hot these stay dissolved, but the oil can only hold so much. When the oil cools, in a cooler, a reservoir or a turbine at rest, the compounds come out of solution and settle on metal surfaces as varnish. Hot spots, entrained air bubbles that collapse under pressure, and electrostatic discharge in fine filters all speed the process up.
Because varnish comes out of solution as oil cools, a system that runs continuously can look clean and then give trouble after a shutdown.
Measuring the risk
The membrane patch colorimetry (MPC) test, ASTM D7843, is the usual measure. A sample of oil is diluted and filtered through a fine membrane, and the colour of the deposit on the patch is measured. The higher the number, the greater the varnish potential. Trend MPC alongside oxidation tests and the oil's remaining antioxidant level, and watch for rising differential pressure on fine filters.
Removing it
A varnish removal unit runs in a side stream from the reservoir and takes out the ageing products before they deposit. Over time, as the oil's capacity to hold them is restored, it also draws back deposits that have already formed on surfaces.
Method | What it removes | Typical use |
|---|---|---|
Adsorption elements | Dissolved ageing products | Turbine and compressor lube oil |
Cooled depth filtration | Suspended varnish, after cooling the oil to bring it out of solution | Systems with heavy varnish |
Ion exchange | Acids and ageing products | Phosphate ester control fluids |
The Vens VH-VRU varnish removal unit offers all three methods, with a 5 µm post-filter and flows to suit the tank.
Keeping it away
Keep the oil cool where you can, and avoid hot spots in the system.
Keep air out of the oil: check suction lines and return line discharge below the oil level.
Keep particle and water levels low with an offline filter unit and desiccant breathers.
Monitor cleanliness continuously with a VH-OCM monitor and test MPC regularly.
What to send us
Tell us the oil, the reservoir volume, the latest MPC result and oil analysis, and the problems you see. We will recommend the method and size the unit.